Microgrid & Energy Storage · Engineered in Shenzhen
IMDC100100 — front view
IMDC100100 — additional view 2
1 / 2
Power Conversion Modules

IMDC100100 5 kW Isolated Bidirectional DC/DC Module

5 kW isolated DC/DC · 200–420 Vdc bus · 32 units in parallel

  • High-frequency isolation handles a ≥2.6:1 bus-to-battery voltage ratio
  • 94% peak efficiency in both charge and discharge directions
  • Up to 32 units share current: one 5 kW block scales to 160 kW
  • 220 × 84 × 400 mm, under 6 kg — one slot in a standard 19-inch subrack
  • Reverse-polarity protection on both battery and bus terminals
Product introduction

Overview & fit.

The IMDC100100 is a 5 kW bidirectional DC/DC converter with high-frequency isolation, packaged for 19-inch rack mounting. Isolation lets the battery sit at a very different potential from the DC bus — the voltage ratio is at least 2.6:1 — without a line-frequency transformer.

01What it does

The module charges a 30–100 Vdc battery from a 200–420 Vdc bus and discharges back with 94% peak efficiency in both directions. Switching between charge, discharge and standby is automatic, and up to 32 units share current in one rack, so a 5 kW building block scales to 160 kW without changing the control architecture.

02Where it fits

  • Telecom and DC power systems running 48 V battery strings on a 370 Vdc bus
  • Rack-based storage where a low-voltage battery must not be referenced to the bus
  • Systems that need hot-swap replacement without shutting the rack down
  • Step-up or step-down between two DC buses at a fixed 2.6:1 or greater ratio
48 Vdc BUSlow-voltage sideDC/DCIMDC100100HIGH-VOLTAGE200–420 VDC busSYSTEM POSITIONBidirectional power flow shown schematically — actual topology depends on site design
Where the IMDC100100 sits in a typical system

03Why this model

At 220 × 84 × 400 mm and under 6 kg, it fits a standard 19-inch subrack at 5 kW per slot. Reverse-polarity protection on both battery and bus terminals prevents the most common commissioning failure in rack builds, where a battery string is landed backwards.

Technical data

Full specifications.

DC bus side
Voltage range200–420 Vdc
Rated voltage370 Vdc
Maximum current17 A
Over-voltage protection≥430 Vdc (recovery ≤420 Vdc)
Under-voltage protection≤180 Vdc
Battery side
Voltage range30–100 Vdc
Rated voltage60 Vdc
Maximum current105 A
Performance
Rated power5 kW
Peak efficiency94% (charge / discharge)
Current regulation≤±5%
Voltage regulation≤±1%
RippleCurrent <5% · voltage <2%
Soft start3–8 s
Standby loss<30 W
Protection & environment
ProtectionBattery and bus reverse polarity · over-current · over-voltage · over-temperature · short circuit
Operating temperature−40 to +60 °C (derating above +50 °C)
Storage temperature−40 to +75 °C
CoolingVariable-speed forced air
Protection ratingIP20
Altitude≤2000 m (derating above)
Dimensions (W×H×D)220 × 84 × 400 mm
Weight<6 kg
Parallel capacityUp to 32 units
CommunicationCAN / RS485
StandardsGB/T 34120 · GB/T 34133 · UL1973 · UL9540

Source: published specification for IMDC100100. Confirm project-specific limits with our engineers before final sizing.

Model-specific documents

Datasheet, GA drawing & terminal schedule.

Issued on request for IMDC100100 — tell us the model and destination country and we will send the current revision.

Related

You may also need.

BAC125K950C
BAC125K950C

BAC125K950C 125 kW Bidirectional PCS (All-SiC)

125 kW all-SiC PCS · 600–950 Vdc battery · 98.8% peak efficiency

BIDC1500100
BIDC1500100

BIDC1500100 125 kW Bidirectional DC/DC Module

125 kW bidirectional DC/DC · 600–1500 V · up to 40 units in parallel

BIDC75050F
BIDC75050F

BIDC75050F 20 kW Bidirectional DC/DC with Integrated MPPT

20 kW non-isolated DC/DC · 260–900 Vdc · MPPT 260–720 Vdc

Ready to size your system?

Send us your DC bus or battery voltage, PV array size, load profile and grid conditions — we will confirm the configuration and parallel scheme.